ASMI TXLP 17

ASMI TXLP 17 is a high-class twin-comductor heating cable, which is designed for charging floor heating in new buildings. The cable is casted inside the concrete slab during the construction.

The power of the cable is 17 W/m. When the cable is installed with intervals of 17 to 20 cm, a heating effect of 80-100 W per square meter is achieved.

Due to the aluminum screen, the cable is very easy to install as it remains in the bent form. The screen protects the cable against mechanical damage during the installation.

Another feature that adds value to the cable is the integrated splice between the heating cable and the cold connection cable (length 2.25 m). The splice is factory-made and it is protected by isolation, aluminum screen and outer jacket. The position of the splice is marked on cable jacket. Also the cold cable is clearly marked on the jacket.

Products

   Type Area Length Power Elec.no.
   ASMI TXLP 17/194 29,5 - 37,0 m2 194 m 3300 W  81 790 52
   ASMI TXLP 17/154 23,5 - 29,5 m2 154 m 2600 W 81 790 51
   ASMI TXLP 17/124 19,0 - 23,5 m2 124 m 2100 W 81 790 50
   ASMI TXLP 17/100 15,5 - 19,0 m2 100 m 1700 W 81 790 48
   ASMI TXLP 17/81 13,0 - 15,5 m2 81 m 1370 W 81 790 46
   ASMI TXLP 17/72 11,0 - 13,0 m2 72 m 1250 W 81 790 44
   ASMI TXLP 17/58 9,0 - 11,0 m2 58 m 1000 W 81 790 42
   ASMI TXLP 17/50 8,0 - 9,0 m2 50 m 840 W 81 790 40
   ASMI TXLP 17/41 6,5 - 8,0 m2 41 m 700 W 81 790 38
   ASMI TXLP 17/35 5,5 - 6,5 m2 35 m 600 W 81 790 36
   ASMI TXLP 17/29 4,5 - 5,5 m2 29 m 500 W 81 790 34
   ASMI TXLP 17/23 3,5 - 4,5 m2 23 m 400 W 81 790 32
   ASMI TXLP 17/17 2,5 - 3,5 m2 17 m 300 W 81 790 30
   ASMI TKXP 17/11 1,5 - 2,5 m2 11 m 200 W 81 790 28

Open brochure

Open and print brochure  "Chargin floor heating" as a pdf file.


Technical Data

Voltage (max)                                      230 V
Power                                                     17 W/m
Temperature (max)
- under voltage                                      60 °C
- uncoupled                                            85 °C
Dimensions                                        6 x 8 mm
Installation temperature (min)           -10 °C
Bending radius                                      40 mm  

Cable Structure

1. Heating wire (copper) with factory-made cold end
2. Ground wire
3. Return wire (copper)
4. Isolation (XLPE plastic)
5. Protective aluminum shield
6. Jacket (blue PVC plastic)